Closed Top Conrete Tank with Closed Top Liner

Installation of the Kentain closed top liner in a closed top tank requires a Kentain supervisor and or crew who are certified for confined space entry.

The prefabricated liner is taken through a manway and unfolded with the top side up. Semi rigid polyethylene tubing is inserted in the cross section hems.

Notches are provided at regular intervals to allow plastic rope to be fastened to the tubing.

A support frame is bolted to the ceiling of the concrete tank and the liner support lines are attached to the frame.

The liner is pulled up and secured in place thus fully suspending the liner inside the tank.

Where flanged fittings are located, the flexible flanged tubes are pulled through the openings and smoothed into place. The liner is then visually inspected upon completion of the installation.


 


Enlarge



Enlarge