Closed Top Conrete
Tank with Closed Top Liner
Installation of the Kentain closed
top liner in a closed top tank requires a Kentain supervisor
and or crew who are certified for confined space entry.
The prefabricated liner is taken through a manway and
unfolded with the top side up. Semi rigid polyethylene
tubing is inserted in the cross section hems.
Notches are provided at regular intervals to allow plastic
rope to be fastened to the tubing.
A support frame is bolted to the ceiling of the concrete
tank and the liner support lines are attached to the
frame.
The liner is pulled up and secured in place thus fully
suspending the liner inside the tank.
Where flanged fittings are located, the flexible flanged
tubes are pulled through the openings and smoothed into
place. The liner is then visually inspected upon completion
of the installation.
|