Kentain flexible PVC liners are designed to make installation a simple, safe and efficient operation. Totally prefabricated at the factory, the Kentain liner can usually be installed in a single day by the customers’ maintenance personnel. You do have the option of using a qualified Kentain supervisor and crew. When dealing with a closed top installation and Kentain qualified supervisor is included. Kentain crews are fully qualified to work in enclosed spaces.

Preparation of the interior of the tank does not require expensive downtime and sand blasting. Simply remove sharp projections and loose scales on the existing tank interior.

Installation of the Kentain open top liner in a closed top tank requires a Kentain qualified supervisor.

The prefabricated liner is taken through a man-way and unfolded with the top side up to expose the hem.

Semi rigid polyethylene tubing is inserted in the hem around the top of the liner. Notches are provided at regular intervals to allow plastic rope to be fasted to the tubing.

The liner is pulled up and secured in place in various ways as shown below.

Where flanged fittings are located, the flexible flange tube is pulled through the opening and smoothed into place.

Image of vertical open tank securing systems (D1) on layout 5 images

Open Top Tank with Open Liner
Kentain flexible PVC liners are designed to make installation a simple, safe and efficient operation. Totally prefabricated at the factory, the Kentain liner can usually be installed in a single day by the customers’ maintenance personnel. You do have the option of using a qualified Kentain supervisor and crew.

Preparation of the interior of the tank does not require expensive downtime and sand blasting. Simply remove sharp projections and loose scales on the existing tank interior.

Installation of the Kentain Open top tank liner is a simple, three step process.

The rolled prefabricated liner is lowered to the bottom of the tank.

The liner is unrolled with the top side up and line attached to the rim of the liner.

The liner is then pulled up over the top of the tank and secured on the outside edge.

Securing the liner in place is accomplished in a n umber of ways as shown below

Closed Top Tank Closed Top Liner
Vertical Tank Info & picture
Closed Tank Closed Liner

Installation of the Kentain closed top liner in a closed top tank requires a Kentain confined space qualified supervisor.

The prefabricated liner is taken through a man-way and unfolded with the top side up. Semi rigid polyethylene tubing is inserted in the cross section hems.

Notches are provided at regular intervals to allow plastic rope to be fasted to the tubing.

The plastic rope is passed through the holes drilled in the tank cover and tied to the tubing. The liner is pulled up and secured in place.

Where flanged fittings are located, the flexible flange tube is pulled through the opening and smoothed into place.

Image of vertical closed tank securing systems (E) on installation images

Pic of top with ropes attached from presentation folder

Horizontal Tank Info & picture

Closed horizontal tank with closed liner

Kentain flexible PVC liners are designed to make installation a simple, safe and efficient operation. Totally prefabricated at the factory, the Kentain liner can usually be installed in a single day by the customers’ maintenance personnel. You do have the option of using a qualified Kentain supervisor and crew. When dealing with a closed top installation and Kentain qualified supervisor is included. Kentain crews are fully qualified to work in enclosed spaces.

Preparation of the interior of the tank does not require expensive downtime and sand blasting. Simply remove sharp projections and loose scales on the existing tank interior.

Installation of the Kentain liner in horizontal tanks requires a confined space qualified Kentain supervisor. The prefabricated flexible Kentain liner is lowered into man-way, spread out with the top side up. The manway flange is raised to the top of the tank and the liner is inflated.

An internal rib cage of plastic hoops and supports is installed and tested.

Downtime is minimized since the tank walls do not have to be sand blasted. All that

Image of horizontal tank from lay out
Pictures of horizontal tank interior from website Hamilton,Ontario horizontal steel tank

Fittings Info & picture
Fittings

Flexible PVC tank liners include flanged tubes joined and sealed at the factory. By folding the flexible flanges, tubes can be inserted through the concrete, wood, FRP or steel walls and pipe fitting. This eliminates most onsite seaming and joining and provides long lasting, chemical resistant protection for the fittings as well as the tank itself. Bag type flexible PVC liners and tubes can be custom made for tanks of any size or shape.


 
1. The bundled liner is lowered through the manhole into the tank.

2. Chemical resistant polypropylene ropes are passed through holes in the tank top and fastened to the ribs on the top of the liner.

3. The liner is hoisted by the ropes into place.

4. The ropes are tied together to secure the liner into position.